Rotanta 460
Hettich Benchtop Centrifuge
Non-Refrigerated/Refrigerated
Hettich Centrifuges Rotanta 460

OPERATING AND FEATURES
  • Accommodates various tube systems from 0.2ml to 750ml as well as Qiagen plates, microtitre plates, micronic systems, culture plates and deep well plates
  • Microprocessor-controlled
“N” CONTROL PANEL (Standard)
  • Clearly arranged, water-protected foil keypad for entering the parameters
  • 3 complete running programs can be stored and recalled
  • Speed RPM: Input in increments of 10
  • Running Time: Input in minutes and seconds, max 99 minutes
  • Impulse key for short centrifuging operations
  • Relative centrifugal force (RCF): Input in increments of 10
  • Change-over RPM/RCF: By entering the rotor radius r/mm the centrifuge will calculate and indicate speed or RCF
  • Run up/run down time: Input of acceleration and braking ramps in levels of 1-9 or unbraked run-down
  • Display of actual values of the parameters during centrifugation
  • Pre-cooling program is standard (CFC-free cooling) with Rotanta 46R model
  • Temperature, T/C°: With Rotanta 460R model, Controllable within a range of -20°C to +40°C. Input in increments of 1°C.
“S” CONTROL PANEL (Optional)
  • Clearly arranged, water protected foil keypad for entering the parameters
  • Ability to store 89 complete running programs
  • Speed RPM: Input in increments of 10
  • Radius (r): Input in mm when speed or RCF need to be determined
  • Running time (t): Input in minutes and seconds, max 999 min.
  • Relative centrifugal force (RCF): Input in increments of 1
  • Run up/Run down time: Input of acceleration and braking ramps in levels of 1-9, or time-controlled in minutes and seconds. 0 = unbraked run-down.
  • Deceleration with brake force cut-off: Input of the cut-off speed in RPM
  • Integral of the centrifugal acceleration: provides continuous information on the are exposed to during centrifugation
  • Pre-cooling program is standard (CFC-free cooling) with Rotanta 460RS model
  • Temperature, T/C°: With Rotanta 460RS model input in increments of 1°C within a range -20°C to +40°C
SAFETY
  • Metal housing and metal lid, paneling finished in scratch and impact resistant coating
  • The Stainless Steel centrifuging chamber is easy to clean while providing additional safety
  • Lid locking
  • Lid holding
  • Lid dropping protection
  • Imbalance switch-off
  • Emergency lid lock release
  • Viewing port in the lid
  • Chamber overheating protection in the Rotanta 460R and Rotanta 460RS
SPEED
  • Max. Speed with angle rotor 15,000 RPM, 24,400 RCF
  • Max. Speed with swing-out rotor 4,600 RPM, 4,779 RCF
Model Weight (Kg) Dimensions W x H x D (mm) Available Voltage Part Number
ROTANTA 460 89.5 554 X 453 X 707
115 V
230 V
5600-01
5600
ROTANTA 460R 125 770 X 453 X 707
115 V
230 V
5605-01
5605

Rotor Number Rotor Type Places Tube Size (mL) Max RCF
5624 SWING-OUT 4 1 - 750mL
4 Deepwell Plates
16Culture Plates
24 Microtiter Plates
4,235
4446 SWING-OUT 6 1.6 - 250mL 3,631
4620 SWING-OUT 2 2 Deepwell Plates
8 Culture Plates
12 Microtiter Plates
5858
6446(460R)
5615 ANGLE 6 1.5 - 94 mL 18,038
4489 ANGLE 30 0.2 - 2.0 ML 24,400
5645 ANGLE 6 250 mL 11,228
14,025(460R)
5616 DISC 6 25 & 50 mL 783 / 805